Rappel concernant les règles de confidentialité de Google
Lire
Résultats de recherche
[PDF]Design of Pedestal Anchorage
www.construccionenacero.com/.../ci33_2122_diseno_del_acero_d...Traduire cette page
de J Owen - Autres articles
Widianto is a structural engineer on the Shell SUEx 1 project. He received his B.S[PDF]Post-installed rebar. - Hilti
https://www.hilti.pt/.../c-rebar/Technical_manual_rebar_EN.pdfTraduire cette page
3 févr. 2014 - Reinforcement anchorages or splices that are fixed into already cured concrete by Hilti HIT injection adhesives in drilled holes are called “Post-installed rebar connections” as opposed to normal, so called “cast-in” reinforcement. Many connections of rebars installed for good detailing practice will not ...Termes manquants : widianto
Anchor Bolt Design Spreadsheet Anchor Reinforcement ACI318-08 ...
www.civilbay.com/.../Design-of-Anchorage-to-Concrete-Using-AC...Traduire cette page
CIVILBAY STRUCTURAL ENGINEERING SPREADSHEET CONCRETE ANCHORAGE ANCHOR BOLT DESIGN.[PPT]Anchorage and Development Length
www.engr.uky.edu/.../14%20-%20Anchorage%20and%20Develop...Traduire cette page
Anchorage and Development Length. Development Length - Tension. Where,. α = reinforcement location factor. β = reinforcement coating factor. γ = reinforcement size factor. λ = lightweight aggregate concrete factor. Ktr = 0 as a design simplification. c = spacing or cover dimension. for further information and values, see ...Termes manquants : widianto
Earthquake Design Considerations for Anchorages in Industrial ...
https://www.researchgate.net/.../267400153_Earthquake_Design_Considerations_for_...
18 déc. 2017 - Full-text (PDF) | Anchorages of tanks, vessels and other significant structures in petrochemical facilities are subject to code requirements and must be engineered so that their design strength equals or exceeds the factored loads from load combinations that include earthquake (seismic) load effec...[PDF]Design of Anchor Reinforcement - NEES Anchor - UWM
nees-anchor.ceas.uwm.edu/S-2011-048%20Design%20of%20Anc...Traduire cette page
de D Petersen - Cité 9 fois - Autres articles
bars along the direction of the shear force close to the top concrete surface as illustrated in Fig. 2. 22. The existing design methods5,7,8 assume that the concrete breakout similar to that observed for. 23. Page 3. 3 anchors in plain concrete occurs before steel reinforcement takes effect. With this assumption,. 1 the shear ...[PDF]29 Concrete Gravity-Based Structure - Idium AS
wpstatic.idium.no/www...no/2016/.../GBS-ACI-Vol38No6_full.pdfTraduire cette page
30 juin 2016 - by Widianto, Jameel Khalifa, Gus Taborda, and Knut Bidne. The Hebron offshore oil development .... vertical post-tensioning anchorage, as anchorage within the top slab thickness would have resulted in .... uninterrupted concrete placement, reinforcing bar installation, and minor surface repair. Slipforming ...Stressed Bars - Anchorage to Concrete - Structural engineering ...
www.eng-tips.com/viewthread.cfm?qid=429942Traduire cette page
13 sept. 2017 - 8 messages - 3 auteurs
Curious - the green-colored vertical rebar, is it sleeved into the crosshead and post-grouted OR cast into the precast crosshead? ... This makes me think that breakout modes of failure are possible and that you should be designing according to principals similar to those set out in this article by Widianto.[04093] - Design of Anchor Reinforcement in Concrete Pedestals.pdf ...
https://www.scribd.com/.../04093-Design-of-Anchor-Reinforceme...Traduire cette page
[04093] - Design of Anchor Reinforcement in Concrete Pedestals.pdf - Download as PDF File (.pdf), Text File (.txt) or read online.